Space Savings: UHFC Passive Data Center in a Single Rack

Sept. 26, 2023

As data center facilities (DC) expand and change to meet increasing processing and storage demands, time, budget, and physical space needs can become tighter and tighter and harder to accommodate. DC facilities managers and techs must find ways to use available floor space (green or brown) to its fullest potential.

To save space in DCs, Sumitomo Electric Lightwave (SEL) has developed several innovations, including the 3RU Rack-Mounted Splice Enclosure. This enclosure, a 2023 Cabling Installation & Maintenance Innovators Awards Gold Level Honoree, supports an entire ultra-high-fiber-count (UHFC) passive data center in a single rack – up to 5,184 fibers when using LC panels. Each Splice Enclosure provides a 144-spliced ribbon (1,728 fibers) capacity within a 3RU space. It is this innovative use of space that facilitates the placement of an entire UHFC passive data center within a single rack.

To save space in DCs, Sumitomo Electric Lightwave (SEL) has developed several innovations, including the 3RU Rack-Mounted Splice Enclosure. This enclosure, a 2023 Cabling Installation & Maintenance Innovators Awards Gold Level Honoree, supports an entire ultra-high-fiber-count (UHFC) passive data center in a single rack – up to 5,184 fibers when using LC panels. Each Splice Enclosure provides a 144-spliced ribbon (1,728 fibers) capacity within a 3RU space. It is this innovative use of space that facilitates the placement of an entire UHFC passive data center within a single rack.

 

Bill of Materials for 5,184-F Data Center (in 54U Rack)

3RU 1728 Splice
3RU 1728 Splice
3RU 1728 Splice
6RU 864 LC Pre-Term Patch Panels
6RU 864 LC Pre-Term Patch Panels
6RU 864 LC Pre-Term Patch Panels
6RU 864 LC Pre-Term Patch Panels
6RU 864 LC Pre-Term Patch Panels
6RU 864 LC Pre-Term Patch Panels

The above example shows the configuration needed to achieve a 5,184-F UHFC passive data center within a single rack using 3RU Rack-Mounted Splice Enclosure (Fig. 1) coupled with 6RU 864 Pre-terminated LC Patch Panels (Fig. 2). The space savings achieved when using this configuration help free up floor space within the data center as a whole and within cages dedicated to customers, allowing for flexibility and scalability to meet demands today and into the future. Additionally, the ability to physically locate all passive components together and ensure the ability to route entering and exiting cables from both overhead and in-floor pathways helps limit contact with network equipment.

 

Consolidating an ultra-high-fiber-count (UHFC) passive data center within a single rack will maximize floor space (white space) while maintaining or improving DC physical security and network flexibility. SEL’s Rack-Mounted Splice Enclosure features innovations and benefits that address these challenges while providing a secure, clean, and cost-efficient distribution point. The enclosure also facilitates a smooth transition between cable formats and fiber counts, protects fiber terminations (bare fibers), and manages excess cable slack.

Learn More

Sponsored Recommendations

Coherent Routing and Optical Transport – Getting Under the Covers

April 11, 2024
Join us as we delve into the symbiotic relationship between IPoDWDM and cutting-edge optical transport innovations, revolutionizing the landscape of data transmission.

Data Center Network Advances

April 2, 2024
Lightwave’s latest on-topic eBook, which AFL and Henkel sponsor, will address advances in data center technology. The eBook looks at various topics, ranging...

From 100G to 1.6T: Navigating Timing in the New Era of High-Speed Optical Networks

Feb. 19, 2024
Discover the dynamic landscape of hyperscale data centers as they embrace accelerated AI/ML growth, propelling a transition from 100G to 400G and even 800G optical connectivity...

Advancing Data Center Interconnect

July 31, 2023
Large and hyperscale data center operators are seeing utility in Data Center Interconnect (DCI) to expand their layer two or local area networks across data centers. But the methods...